TrendIC B.V., Waddinxveen | The Netherlands
+31 182 613945 | https://www.trendic.nl | support@trendic.nl
ICTestAutomation Application Configuration Notes
This chapter contains a description and examples of most of the configuration settings applicable to the various ICTestAutomation applications.
Be careful in changing these configuration settings as they influence the behavior of the ICTestAutomation applications!
ICDefine module
ICDefine application config
The ICDefine application config file is located in the ICDefine program folder and is named TrendIC.ICDefine.exe.config.
The file is in XML format and the application config settings are located in the <appSettings> section. Below are the most used settings and their explanation.
The general format of a configuration setting is
<add key="<key>" value="<value>" />
Any keys present in the <appSettings> section but not mentioned in the description below are not intended to be changed by the customer unless specifically instructed by TrendIC Support or TrendIC Consultancy.
BaseDir
Path to the SUT tree
C:\WorkSpaces\User\CitraTest\SUT
IniFile
Name of the SUT release config file
tft-citratest.ini
TimeOut
Maximum runtime of a single testrun in milliseconds
600000
Autosave
Automatically save test case after editing before it runs
True
HelpURL
URL to the (online) helpfile
http://wiki.trendic.nl/doku.php?id=start:[START_ID]&u=citratest&p=ICTest2c#
FunctionKeyCaptureImage
Shortkey for image capture
F8
FunctionKeyQuickBuild
Shortkey for Quick Build function
F9
FunctionKeyAutoRun
Shortkey to run test case, see also AutoSave
CTRL+F10
FunctionKeyAutoRunMovie
Shortkey to run test case and record movie
CTRL+SHIFT+F10
Runner
Full path and filename of the CitraTest Runner program
C:\Program Files (x86)\ICTestAutomation\ICRunner\TftCitraTestRunner.exe
EditMovieApplic
Full path and filename of the movie editor program
C:\Program Files (x86)\Blueberry Software\BB FlashBack\Express 5\FlashBack Player.exe
DebugLogDll
Create debug logfile of test case run (True) or not (False)
False
AutoFillLabelProperty
Automatically fill function description field while editing test case
True
<FunctionName>
Automatically fill the specified function's description field; see also AutoFillLabelProperty
Key {} and Enter
If AutoFillLabelProperty is True the editor fills the function's Description field as specified by <value> replacing {} by the contents of the object, e.g.:
Function: Key Text: Example
.
results in:
Description: Key Example and Enter
Note that the {} identifier may occur anywhere in the description string or it may be omitted. If the object is a memory or .ini variable, the identifier is not replaced.
SUT release config
The SUT release config file is located in the SUT\<sut>\Releases\<release>\config folder; its default name is tft-citratest.ini.
The file is in standard .ini format, so consists of section headers, keywords and values, e.g.:
[<section x>] <keyword 1>=<value 1> <keyword 2>=<value 2> ... [<section y>] <keyword 8>=<value 8> <keyword 9>=<value 9> ...
Any sections or keywords present in the .ini file but not mentioned in the description below are not intended to be changed by the customer unless specifically instructed by TrendIC Support or TrendIC Consultancy.
[environment] section
testDataFile
Full path and filename of the testdata file
C:\WorkSpaces\User\CitraTest\SUT\Tests_8.4\Testdata\testdata.ini
UseColorTransitions
Apply CitraTest enhanced image color transition (1) or not (0 )
1
ColorTolerance
Specifies the CitraTest enhanced image color tolerance
70
PercentageError
Specifies the maximum allowable percentage of pixel mismatches during image comparison
2
[appstart] section
startapplic
Activates the specified application at test case start (1) or not (0)
1
application
The full path and filename of the application to be started before test case run
C:\Program Files\Internet Explorer\iexplore.exe
arguments
Any argument to be passed to the specified application at startup
https://www.trendic.nl
startupDirectory
Startup directory of the specified application
C:\Program Files\Internet Explorer\
app-available
Name of image file to check if specified application is started
AppStarted.bmp
app-active
Name of image file to check if specified application is active
AppActive.bmp
app-not-active
Name of image file to check if specified application is inactive
AppInactive.bmp
username
The username to login specified application, if any
password
The password to login specified application, if any
ICConsole module
ICConsole application config
The ICConsole application config file is located in the ICConsole program folder and is named TrendIC.ICConsole.exe.config.
The file is in XML format and the application config settings are located in the <appSettings> section. Below are the most used settings and their explanation.
The general format of a configuration setting is
<add key="<key>" value="<value>" />
Any keys present in the <appSettings> section but not mentioned in the description below are not intended to be changed by the customer unless specifically instructed by TrendIC Support or TrendIC Consultancy.
RunnerFilePath
Full path and filename of the CitraTest Runner program
C:\Program Files (x86)\ICTestAutomation\ICRunner\TftCitraTestRunner.exe
RunnerExecutionTimeOutInSeconds
Maximum runtime of a single testrun in seconds
3600
ExecuteBacklogScheduledTestRunsInMinutes
Maximum backlog in minutes of scheduled but not yet executed testruns
60
QueryScheduledScenariosInSeconds
Interval in seconds between queries for scheduled scenarios
45
QueryKilledTestRunsInSeconds
Interval in seconds between queries for killed testruns
60
DebugLogDll
Create debug logfile of test case run (True) or not (False)
False
ICPortal module
ICPortal web application config
The ICPortal web application config file is located in the ICPortal application folder (which defaults to C:\inetpub\wwwroot\ICPortal) and is named web.config.
The file is in XML format and the application config settings are located in the <appSettings> section. Below are the most used settings and their explanation.
The general format of a configuration setting is
<add key="<key>" value="<value>" />
Any keys present in the <appSettings> section but not mentioned in the description below are not intended to be changed by the customer unless specifically instructed by TrendIC Support or TrendIC Consultancy.
ICPortalBaseDirWorkspaces
Path to the SUT tree
S:\WorkSpaces\User\CitraTest\SUT
ICPortalVirtualDirScreenFailures
Links the virtual directory to the actual directory for screen captures at test run failure
/ScriptFailScreenCaptures/
ICPortal Maintenance application config
Depending the run type of the ICPortal Maintenance application, it uses one of two possible config files, which are located in the ICPortal Maintenance application folder. Run type Batch uses the config file named TrendIC.Portal.Maintenance.Batch.exe.config and run type Service uses the config file named TrendIC.Portal.Maintenance.Service.exe.config.
Either file is in XML format and the application config settings are located in the <appSettings> section. The only used setting for both run types and its explanation is listed below.
The general format of a configuration setting is
<add key="<key>" value="<value>" />
Any keys present in the <appSettings> section but not mentioned in the description below are not intended to be changed by the customer unless specifically instructed by TrendIC Support or TrendIC Consultancy.
NumberOfDaysToKeepData
Test results older than the specified number of days are deleted from the ICPortal database
180
ICPortal RunNow application config
The ICPortal RunNow application config file is located in the ICPortal RunNow application folder and is named TrendIC.ICPortal.RunNow.exe.config.
The file is in XML format and the application config settings are located in the <appSettings> section. Below is the only config setting and its explanation.
The general format of a configuration setting is
<add key="<key>" value="<value>" />
Any keys present in the <appSettings> section but not mentioned in the description below are not intended to be changed by the customer unless specifically instructed by TrendIC Support or TrendIC Consultancy.
WebApiBaseURL
URL to the ICPortal web application
http://TRENDIC-1/ICPortal/